Reduce ID errors with 24/7 phlebotomy
Reduce ID errors with 24/7 phlebotomy
There are ways to minimize labeling errors. Top strategies include bar coding technology, firm policies and procedures, and accounting for the human factors that can prompt errors. Research also suggests that establishing a 24-hour, seven-days-a-week phlebotomy service can reduce errors by leaving blood draws to the people best trained and focused on the task.
Ana K. Stankovic, MD, PhD, MSPH, vice president of medical and scientific affairs and clinical operations with BD Diagnostics, based in Franklin Lakes, NJ, conducted research that involved reviewing more than 3.3 million specimen labels from 147 laboratories.1 Labeling errors were identified at a rate of 0.92 per 1,000 labels. Two variables were statistically associated with lower labeling error rates: laboratories with current, ongoing quality monitors for specimen identification; and institutions with 24/7 phlebotomy services for inpatients.
Most institutions had written policies for specimen labeling at the bedside or in outpatient phlebotomy areas (96% and 98%, respectively). Stankovic and her colleagues concluded that establishing quality metrics for specimen labeling and deploying 24/7 phlebotomy operations might contribute to improving the accuracy of specimen labeling for the clinical laboratory.
"Dedicated phlebotomists are much better because they are better trained and they are not distracted by needing to do a hundred other things," Stankovic says. "We see hospitals transitioning back to dedicated phlebotomists because they are finding that the front-end costs are offset by the back-end costs of errors, redraws, and other problems."
In addition, patient specimens should include two distinct identifiers, and one should be a number, Stankovic says. For example, the label can include the patient's name and birth date, or name and Social Security number. Using both will help eliminate confusion when patients have similar names, she says.
Reference
- Wagar EA, Stankovic AK, Raab S, et al. Specimen labeling errors: A Q-probes analysis of 147 clinical laboratories. Arch Pathol Lab Med 2008; 132:1,617-1,622.
Subscribe Now for Access
You have reached your article limit for the month. We hope you found our articles both enjoyable and insightful. For information on new subscriptions, product trials, alternative billing arrangements or group and site discounts please call 800-688-2421. We look forward to having you as a long-term member of the Relias Media community.